Features
Support of DS0 DACS (Digital Access Cross-Connect System) with full cross-connect
Dual controller, dual power (?8V DC) with load sharing
1 for 1 protection, Y-BOX
1 for 1 protection, E1, T1, FOM
PDH ring protection, QE1, QT1, FOM, Mini QE1
Console, Telnet, SLIP, SNMP, and Inband management support
Craft interface port for connection to external LCD display
Compatible to a SNMP based GUI network management system and supported by LoopView and Loop iNMS
Dual controller, dual power (?8V DC) with load sharing
1 for 1 protection, Y-BOX
1 for 1 protection, E1, T1, FOM
PDH ring protection, QE1, QT1, FOM, Mini QE1
Console, Telnet, SLIP, SNMP, and Inband management support
Craft interface port for connection to external LCD display
Compatible to a SNMP based GUI network management system and supported by LoopView and Loop iNMS
Specification
Model (non RoHS compliant)
Model (RoHS compliant)
Description
Note
Main Unit
Loop-AM3490-CHA
Loop-AM3490-CHA-G
Wideband Main Unit without CPU, power, E1/T1 card
AM3440-A type Chassis
CPU Module
Loop-AM3490-CCA-T
Loop-AM3490-CCA-T-G
CPU card with T1 External Clock (order two for redundancy)
Loop-AM3490-CCA-E
Loop-AM3490-CCA-E-G
CPU card with E1 External Clock (order two for redundancy)
Mini Plug-in Module (Select 1 to 4 cards from list below)
Loop-AM3490-E1
Loop-AM3490-E1-G
E1 Interface
Loop-AM3490-T1
Loop-AM3490-T1-G
T1 Interface
Loop-AM3490-M4E75
Loop-AM3490-M4E75-G
Mini Quad E1 Interface
w/ 75 ohm
Includes a 1 meter DB25 to 8-BNC Conversion Cable
For AM3490-CHA and
Loop-AM3490-M4E120
Loop-AM3490-M4E120-G
Mini Quad E1 Interface
w/ 120 ohm
Includes a 1 meter DB25 to 4-RJ48C Jack Conversion Cable
Loop-AM3490-AFRE
Loop-AM3490-AFRE-G
E1 Frame Relay to ATM inter-working or
Frame Relay to Frame Relay concentration
Loop-AM3490-AFRT
Loop-AM3490-AFRT-G
T1 Frame Relay to ATM inter-working or
Frame Relay to Frame Relay concentration
Loop-AM3490-RT
Loop-AM3490-RT-G
Router / Bridge Card
Loop-AM3490-RTA
Loop-AM3490-RTA-G 64 WAN ports router/bridge card
Loop-AM3490-FOM-OPT
Loop-AM3490-FOM-OPT-G
Fiber Optical Interface
Single Slot Plug-in Module
Loop-AM3490-4E1-cc
Loop-AM3490-4E1-cc-G
4-channel E1 Interface
where cc = RJ for RJ48C connector
BNC for BNC connector
Loop-AM3490-4T1
Loop-AM3490-4T1-G
4-channel T1 Interface
Loop-AM3490-6U
Loop-AM3490-6U-G
6-channel IDSL plug-in module
Loop-AM3490-10U
Loop-AM3490-10U-G
10-channel IDSL plug-in module
Loop-AM3490-3HA
Loop-AM3490-3HA-G
3-channel 6Mbits MDSL plug-in module without line power source (2Mbits per channel)
Loop-AM3490-2GH
Loop-AM3490-2GH-G
2-channel G.SHDSL plug-in module (2 pair)
Loop-AM3490-4GH
Loop-AM3490-4GH-G
4-channel G.SHDSL plug-in module (1 pair)
Loop-AM3490-8CD
Loop-AM3490-8CD-G
8-channel G.703 Interface at 64 Kbps data rate
Loop-AM3490-8DC
Loop-AM3490-8DC-G
8-channel dry contact I/O plug-in module
Loop-AM3490-8EM-x
Loop-AM3490-8EM-x-G
8-channel 2W/4W E&M plug-in module
Loop-AM3490-12FXS
Loop-AM3490-12FXS-G
12-channel FXS plug-in module with 600/ 900 Impedance, Battery Reverse, PLAR, without Ground Start and Metering Pulse
12FXS cards are for use with 48VDC power module only.
12FXS-GM includes all function of FXS Cards, except 12FXS-P and 12FXS-GMP.
Loop-AM3490-12FXS-P
Loop-AM3490-12FXS-P-G
12-channel FXS plug-in module with 600/ 900 Impedance, Battery Reverse, PLAR, without Ground Start and Metering Pulse
PLAR bit programmable function
Loop-AM3490-12FXS-M
Loop-AM3490-12FXS-M-G
12-channel FXS plug-in module with 600/ 900 Impedance, Battery Reverse, PLAR, [Metering Pulse]
Loop-AM3490-12FXS-MP
Loop-AM3490-12FXS-MP-G
12-channel FXS plug-in module with 600/ 900 Impedance, Battery Reverse, PLAR and PLAR bit programmable function, [Metering Pulse]
Loop-AM3490-12FXS-GS
Loop-AM3490-12FXS-GS-G
12-channel FXS plug-in module with 600/ 900 Impedance, Battery Reverse, PLAR, [Ground Start]
Loop-AM3490-12FXS-GM
Loop-AM3490-12FXS-GM-G
12-channel FXS plug-in module with 600/ 900 Impedance, Battery Reverse, PLAR, [Ground Start, and Metering Pulse]
Loop-AM3490-12FXS-GMP
Loop-AM3490-12FXS-GMP-G
12-channel FXS plug-in module with 600/ 900 Impedance, Battery Reverse, PLAR and PLAR bit programmable function, [Ground Start, and Metering Pulse]
Loop-AM3490-12FXO
Loop-AM3490-12FXO-G
12-channel FXO plug-in module with 600/ 900 Impedance, Battery Reverse, without Ground Start and Metering Pulse
12FXO-GM includes all FXO Card functions.
Loop-AM3490-12FXO-M
Loop-AM3490-12FXO-M-G
12-channel FXO plug-in module with 600/ 900 Impedance, Battery Reverse, [ Metering Pulse ]
Loop-AM3490-12FXO-GS
Loop-AM3490-12FXO-GS-G
12-channel FXO plug-in module with 600/ 900 Impedance, Battery Reverse, [ Ground Start ]
Loop-AM3490-12FXO-GM
Loop-AM3490-12FXO-GM-G
12-channel FXO plug-in module with 600/ 900 Impedance, Battery Reverse, [ Ground Start, and Metering Pulse ]
Loop-AM3490-12MAG-1G
Loop-AM3490-12MAG-1G-G
12-channel Magneto plug-in module with L1. GND
12MAG-1G2 includes all MAG Card functions.
Loop-AM3490-12MAG-12
Loop-AM3490-12MAG-12-G
12-channel Magneto plug-in module with L1, L2
Loop-AM3490-12MAG-1G2
Loop-AM3490-12MAG-1G2-G
12-channel Magneto plug-in module with L1, L2, and L1. GND
Loop-AM3490-1C37
Loop-AM3490-1C37-G
1- channel C37.94 plug-in module
Loop-AM3490-4C37
Loop-AM3490-4C37-G
4- channel C37.94 plug-in module
Loop-AM3490-ODP
Not available
8-channel OCU-DP plug-in module
Dual Slot Plug-in Module
Loop-AM3490-6X21A
Loop-AM3490-6X21A-G
6-channel X.21/V.11 card with DB15 connector
Loop-AM3490-6V35A
Loop-AM3490-6V35A-G
6-channel V.35 plug-in modules with DB25S connector, for M34 please order conversion cable connector below.
(2Mbits per channel)
Loop-AM3490-6V36A
Loop-AM3490-6V36A-G
6-channel V.36 card with DB25 connector via conversion cable to DB37
Loop-AM3490-6E530A
Loop-AM3490-6E530A-G
6-channel EIA530 card with DB25 connector
Loop-AM3490-6RS449A
Loop-AM3490-6RS449A-G
6-channel EIA530 card with DB25 connector via conversion cable to DB37
Loop-AM3490-5RS232
Loop-AM3490-5RS232-G
5-channel RS232 with X.50 subrate plug-in module
Loop-AM3490-24FXS
Loop-AM3490-24FXS-G
24-channel FXS plug-in module with /600/ 900 Impedance, Battery Reverse, PLAR, without Ground Start and Metering Pulse
24FXS-GM includes all function of FXS Cards, except 24FXS-P and 24FXS-GMP.
24FXS cards are for use with 48VDC power module only.
Loop-AM3490-24FXS-P
Loop-AM3490-24FXS-P-G
24-channel FXS plug-in module with 600/ 900 Impedance, Battery Reverse, PLAR, without Ground Start and Metering Pulse
PLAR bit programmable function
Loop-AM3490-24FXS-M
Loop-AM3490-24FXS-M-G
24-channel FXS plug-in module with 600/ 900 Impedance, Battery Reverse, PLAR, [Metering Pulse]
Loop-AM3490-24FXS-GS
Loop-AM3490-24FXS-GS-G
24-channel FXS plug-in module with 600/ 900 Impedance, Battery Reverse, PLAR, [Ground Start]
Loop-AM3490-24FXS-GM
Loop-AM3490-24FXS-GM-G
24-channel FXS plug-in module with 600/ 900 Impedance, Battery Reverse, PLAR, [Ground Start, and Metering Pulse]
Loop-AM3490-24FXS-GMP
Loop-AM3490-24FXS-GMP-G
24-channel FXS plug-in module with 600/ 900 Impedance, Battery Reverse, PLAR and PLAR bit programmable function, [Ground Start, and Metering Pulse]
Loop-AM3490-24FXO
Loop-AM3490-24FXO-G
24-channel FXO plug-in module with 600/ 900 Impedance, Battery Reverse, without Ground Start and Metering Pulse
24FXO-GM includes all FXO Card functions.
Loop-AM3490-24FXO-M
Loop-AM3490-24FXO-M-G
24-channel FXO plug-in module with 600/ 900 Impedance, Battery Reverse, [Metering Pulse]
Loop-AM3440-24FXO-GS
Loop-AM3440-24FXO-GS-G
24-channel FXO plug-in module with 600/ 900 Impedance, Battery Reverse, [Ground Start]
Loop-AM3490-24FXO-GM
Loop-AM3490-24FXO-GM-G
24-channel FXO plug-in module with 600/ 900 Impedance, Battery Reverse, [Ground Start, and Metering Pulse]
Loop-AM3490-3HAL
Not available
3-channel 6Mbits MDSL plug-in module with line power source
Factory installed option available with -48 Vdc powered chassis only.
Fan tray required.
For AM3490-CHA only
Loop-AM3490-2GHL
Not available
2-channel G.SHDSL plug-in module with line power source (140 VDC, 110mA), (2 pair)
Factory installed option available with -48 Vdc powered chassis only.
With line power, takes 2 DTE slots per card.
Fan tray required.
For AM3490-CHA only
Loop-AM3490-4GHL
Not available
4-channel G.SHDSL plug-in module with line power source (190 VDC, 60mA), (1 pair)
Factory installed option available with -48 Vdc powered chassis only.
With line power, takes 2 DTE slots per card.
Fan tray required.
For AM3490-CHA only
Power Module
Loop-AM3490-S5
Loop-AM3490-S5-G
Single ?8V DC Power Module (150W UM5613)
Order 2 single DC for dual DC application.
For AM3490-CHA only
Loop-AM3490-S524
Loop-AM3490-S524-G
Single ?4V DC Power Module (150W UM5603)
Cannot be used with FXS Card or MAG card.
For AM3490-CHA only
Loop-AM3490-SDB
Loop-AM3490-SDB-G
Single ?8V DC Power Module (100W)
Order 2 single DC for redundancy
For AM3490-CHB only
Adaptor
Loop-ACC-APA-150
Loop-ACC-APA-150-G
AC (100-240 Vac) to DC (48 Vdc = 3.3A) adaptor for USA
Loop-ACC-APE-150
Loop-ACC-APE-150-G
AC (100-240 Vac) to DC (48 Vdc = 3.3A) adaptor for Europe
Loop-ACC-APU-150
Loop-ACC-APU-150-G
AC (100-240 Vac) to DC (48 Vdc = 3.3A) adaptor for UK
Y-Box
Loop-VV-B
Loop-VV-B-G
1 for 1 protection Y-Box with BNC connectors (4-E1)
Used with 4E1
Loop-VV-R
Loop-VV-R-G
1 for 1 protection Y-Box with RJ48C connectors (16-E1)
Used with 4E1
Loop-VV-T
Loop-VV-T-G
1 for 1 protection Y-Box with RJ48C connectors (16-T1)
Used with 4T1
Model (RoHS compliant)
Description
Note
Main Unit
Loop-AM3490-CHA
Loop-AM3490-CHA-G
Wideband Main Unit without CPU, power, E1/T1 card
AM3440-A type Chassis
CPU Module
Loop-AM3490-CCA-T
Loop-AM3490-CCA-T-G
CPU card with T1 External Clock (order two for redundancy)
Loop-AM3490-CCA-E
Loop-AM3490-CCA-E-G
CPU card with E1 External Clock (order two for redundancy)
Mini Plug-in Module (Select 1 to 4 cards from list below)
Loop-AM3490-E1
Loop-AM3490-E1-G
E1 Interface
Loop-AM3490-T1
Loop-AM3490-T1-G
T1 Interface
Loop-AM3490-M4E75
Loop-AM3490-M4E75-G
Mini Quad E1 Interface
w/ 75 ohm
Includes a 1 meter DB25 to 8-BNC Conversion Cable
For AM3490-CHA and
Loop-AM3490-M4E120
Loop-AM3490-M4E120-G
Mini Quad E1 Interface
w/ 120 ohm
Includes a 1 meter DB25 to 4-RJ48C Jack Conversion Cable
Loop-AM3490-AFRE
Loop-AM3490-AFRE-G
E1 Frame Relay to ATM inter-working or
Frame Relay to Frame Relay concentration
Loop-AM3490-AFRT
Loop-AM3490-AFRT-G
T1 Frame Relay to ATM inter-working or
Frame Relay to Frame Relay concentration
Loop-AM3490-RT
Loop-AM3490-RT-G
Router / Bridge Card
Loop-AM3490-RTA
Loop-AM3490-RTA-G 64 WAN ports router/bridge card
Loop-AM3490-FOM-OPT
Loop-AM3490-FOM-OPT-G
Fiber Optical Interface
Single Slot Plug-in Module
Loop-AM3490-4E1-cc
Loop-AM3490-4E1-cc-G
4-channel E1 Interface
where cc = RJ for RJ48C connector
BNC for BNC connector
Loop-AM3490-4T1
Loop-AM3490-4T1-G
4-channel T1 Interface
Loop-AM3490-6U
Loop-AM3490-6U-G
6-channel IDSL plug-in module
Loop-AM3490-10U
Loop-AM3490-10U-G
10-channel IDSL plug-in module
Loop-AM3490-3HA
Loop-AM3490-3HA-G
3-channel 6Mbits MDSL plug-in module without line power source (2Mbits per channel)
Loop-AM3490-2GH
Loop-AM3490-2GH-G
2-channel G.SHDSL plug-in module (2 pair)
Loop-AM3490-4GH
Loop-AM3490-4GH-G
4-channel G.SHDSL plug-in module (1 pair)
Loop-AM3490-8CD
Loop-AM3490-8CD-G
8-channel G.703 Interface at 64 Kbps data rate
Loop-AM3490-8DC
Loop-AM3490-8DC-G
8-channel dry contact I/O plug-in module
Loop-AM3490-8EM-x
Loop-AM3490-8EM-x-G
8-channel 2W/4W E&M plug-in module
Loop-AM3490-12FXS
Loop-AM3490-12FXS-G
12-channel FXS plug-in module with 600/ 900 Impedance, Battery Reverse, PLAR, without Ground Start and Metering Pulse
12FXS cards are for use with 48VDC power module only.
12FXS-GM includes all function of FXS Cards, except 12FXS-P and 12FXS-GMP.
Loop-AM3490-12FXS-P
Loop-AM3490-12FXS-P-G
12-channel FXS plug-in module with 600/ 900 Impedance, Battery Reverse, PLAR, without Ground Start and Metering Pulse
PLAR bit programmable function
Loop-AM3490-12FXS-M
Loop-AM3490-12FXS-M-G
12-channel FXS plug-in module with 600/ 900 Impedance, Battery Reverse, PLAR, [Metering Pulse]
Loop-AM3490-12FXS-MP
Loop-AM3490-12FXS-MP-G
12-channel FXS plug-in module with 600/ 900 Impedance, Battery Reverse, PLAR and PLAR bit programmable function, [Metering Pulse]
Loop-AM3490-12FXS-GS
Loop-AM3490-12FXS-GS-G
12-channel FXS plug-in module with 600/ 900 Impedance, Battery Reverse, PLAR, [Ground Start]
Loop-AM3490-12FXS-GM
Loop-AM3490-12FXS-GM-G
12-channel FXS plug-in module with 600/ 900 Impedance, Battery Reverse, PLAR, [Ground Start, and Metering Pulse]
Loop-AM3490-12FXS-GMP
Loop-AM3490-12FXS-GMP-G
12-channel FXS plug-in module with 600/ 900 Impedance, Battery Reverse, PLAR and PLAR bit programmable function, [Ground Start, and Metering Pulse]
Loop-AM3490-12FXO
Loop-AM3490-12FXO-G
12-channel FXO plug-in module with 600/ 900 Impedance, Battery Reverse, without Ground Start and Metering Pulse
12FXO-GM includes all FXO Card functions.
Loop-AM3490-12FXO-M
Loop-AM3490-12FXO-M-G
12-channel FXO plug-in module with 600/ 900 Impedance, Battery Reverse, [ Metering Pulse ]
Loop-AM3490-12FXO-GS
Loop-AM3490-12FXO-GS-G
12-channel FXO plug-in module with 600/ 900 Impedance, Battery Reverse, [ Ground Start ]
Loop-AM3490-12FXO-GM
Loop-AM3490-12FXO-GM-G
12-channel FXO plug-in module with 600/ 900 Impedance, Battery Reverse, [ Ground Start, and Metering Pulse ]
Loop-AM3490-12MAG-1G
Loop-AM3490-12MAG-1G-G
12-channel Magneto plug-in module with L1. GND
12MAG-1G2 includes all MAG Card functions.
Loop-AM3490-12MAG-12
Loop-AM3490-12MAG-12-G
12-channel Magneto plug-in module with L1, L2
Loop-AM3490-12MAG-1G2
Loop-AM3490-12MAG-1G2-G
12-channel Magneto plug-in module with L1, L2, and L1. GND
Loop-AM3490-1C37
Loop-AM3490-1C37-G
1- channel C37.94 plug-in module
Loop-AM3490-4C37
Loop-AM3490-4C37-G
4- channel C37.94 plug-in module
Loop-AM3490-ODP
Not available
8-channel OCU-DP plug-in module
Dual Slot Plug-in Module
Loop-AM3490-6X21A
Loop-AM3490-6X21A-G
6-channel X.21/V.11 card with DB15 connector
Loop-AM3490-6V35A
Loop-AM3490-6V35A-G
6-channel V.35 plug-in modules with DB25S connector, for M34 please order conversion cable connector below.
(2Mbits per channel)
Loop-AM3490-6V36A
Loop-AM3490-6V36A-G
6-channel V.36 card with DB25 connector via conversion cable to DB37
Loop-AM3490-6E530A
Loop-AM3490-6E530A-G
6-channel EIA530 card with DB25 connector
Loop-AM3490-6RS449A
Loop-AM3490-6RS449A-G
6-channel EIA530 card with DB25 connector via conversion cable to DB37
Loop-AM3490-5RS232
Loop-AM3490-5RS232-G
5-channel RS232 with X.50 subrate plug-in module
Loop-AM3490-24FXS
Loop-AM3490-24FXS-G
24-channel FXS plug-in module with /600/ 900 Impedance, Battery Reverse, PLAR, without Ground Start and Metering Pulse
24FXS-GM includes all function of FXS Cards, except 24FXS-P and 24FXS-GMP.
24FXS cards are for use with 48VDC power module only.
Loop-AM3490-24FXS-P
Loop-AM3490-24FXS-P-G
24-channel FXS plug-in module with 600/ 900 Impedance, Battery Reverse, PLAR, without Ground Start and Metering Pulse
PLAR bit programmable function
Loop-AM3490-24FXS-M
Loop-AM3490-24FXS-M-G
24-channel FXS plug-in module with 600/ 900 Impedance, Battery Reverse, PLAR, [Metering Pulse]
Loop-AM3490-24FXS-GS
Loop-AM3490-24FXS-GS-G
24-channel FXS plug-in module with 600/ 900 Impedance, Battery Reverse, PLAR, [Ground Start]
Loop-AM3490-24FXS-GM
Loop-AM3490-24FXS-GM-G
24-channel FXS plug-in module with 600/ 900 Impedance, Battery Reverse, PLAR, [Ground Start, and Metering Pulse]
Loop-AM3490-24FXS-GMP
Loop-AM3490-24FXS-GMP-G
24-channel FXS plug-in module with 600/ 900 Impedance, Battery Reverse, PLAR and PLAR bit programmable function, [Ground Start, and Metering Pulse]
Loop-AM3490-24FXO
Loop-AM3490-24FXO-G
24-channel FXO plug-in module with 600/ 900 Impedance, Battery Reverse, without Ground Start and Metering Pulse
24FXO-GM includes all FXO Card functions.
Loop-AM3490-24FXO-M
Loop-AM3490-24FXO-M-G
24-channel FXO plug-in module with 600/ 900 Impedance, Battery Reverse, [Metering Pulse]
Loop-AM3440-24FXO-GS
Loop-AM3440-24FXO-GS-G
24-channel FXO plug-in module with 600/ 900 Impedance, Battery Reverse, [Ground Start]
Loop-AM3490-24FXO-GM
Loop-AM3490-24FXO-GM-G
24-channel FXO plug-in module with 600/ 900 Impedance, Battery Reverse, [Ground Start, and Metering Pulse]
Loop-AM3490-3HAL
Not available
3-channel 6Mbits MDSL plug-in module with line power source
Factory installed option available with -48 Vdc powered chassis only.
Fan tray required.
For AM3490-CHA only
Loop-AM3490-2GHL
Not available
2-channel G.SHDSL plug-in module with line power source (140 VDC, 110mA), (2 pair)
Factory installed option available with -48 Vdc powered chassis only.
With line power, takes 2 DTE slots per card.
Fan tray required.
For AM3490-CHA only
Loop-AM3490-4GHL
Not available
4-channel G.SHDSL plug-in module with line power source (190 VDC, 60mA), (1 pair)
Factory installed option available with -48 Vdc powered chassis only.
With line power, takes 2 DTE slots per card.
Fan tray required.
For AM3490-CHA only
Power Module
Loop-AM3490-S5
Loop-AM3490-S5-G
Single ?8V DC Power Module (150W UM5613)
Order 2 single DC for dual DC application.
For AM3490-CHA only
Loop-AM3490-S524
Loop-AM3490-S524-G
Single ?4V DC Power Module (150W UM5603)
Cannot be used with FXS Card or MAG card.
For AM3490-CHA only
Loop-AM3490-SDB
Loop-AM3490-SDB-G
Single ?8V DC Power Module (100W)
Order 2 single DC for redundancy
For AM3490-CHB only
Adaptor
Loop-ACC-APA-150
Loop-ACC-APA-150-G
AC (100-240 Vac) to DC (48 Vdc = 3.3A) adaptor for USA
Loop-ACC-APE-150
Loop-ACC-APE-150-G
AC (100-240 Vac) to DC (48 Vdc = 3.3A) adaptor for Europe
Loop-ACC-APU-150
Loop-ACC-APU-150-G
AC (100-240 Vac) to DC (48 Vdc = 3.3A) adaptor for UK
Y-Box
Loop-VV-B
Loop-VV-B-G
1 for 1 protection Y-Box with BNC connectors (4-E1)
Used with 4E1
Loop-VV-R
Loop-VV-R-G
1 for 1 protection Y-Box with RJ48C connectors (16-E1)
Used with 4E1
Loop-VV-T
Loop-VV-T-G
1 for 1 protection Y-Box with RJ48C connectors (16-T1)
Used with 4T1
Safety/Quality Approvals
Dimensions 432.4 x 220 x 223.5 mm (WHD)
Power Single/ Dual -48V DC, 100 Watts max (DISCONTINUED).
Single/ Dual -48V DC, 150 Watts max.
Single/ Dual -24V DC, 150 Watts max
Temperature 0-50癈 0-50癈
Humidity 0-95%RH (non-condensing)
Mounting Desk-top stackable, 19?/23?rack mountable
Line Power Supply (For MDSL card and G.SHDSL card only) Available only with DC power.
Power Consumption Max 110 Watt
Power Single/ Dual -48V DC, 100 Watts max (DISCONTINUED).
Single/ Dual -48V DC, 150 Watts max.
Single/ Dual -24V DC, 150 Watts max
Temperature 0-50癈 0-50癈
Humidity 0-95%RH (non-condensing)
Mounting Desk-top stackable, 19?/23?rack mountable
Line Power Supply (For MDSL card and G.SHDSL card only) Available only with DC power.
Power Consumption Max 110 Watt
Other 1
OPT = Description Note
SAA Single optical module with dual uni-directional fiber, 1310 nm,
SC optical connector, 30 km reach (20dB) - S1.1 Use dual fiber
Units delivered ITU-T G.957 application code
SBB Single optical module with dual uni-directional fiber, 1310 nm,
SC optical connector, 50 km reach (30dB) - L1.1
SCC Single optical module with dual uni-directional fiber, 1310 nm,
FC optical connector, 30 km reach (20dB) - S1.1
SDD Single optical module with dual uni-directional fiber, 1550 nm,
SC optical connector, 20 km reach (12dB) - S1.2
SEE Single optical module with dual uni-directional fiber, 1550 nm,
SC optical connector, 100 km reach (40dB) - L1.2
SSM Single optical module with single bi-directional fiber (master),
1310 nm transmit and 1550 receive, SC optical connector,
30 km reach (20dB) - S1.1/ S1.2 1310 nm from master to slave
Order SSM to use with SSS
Use 1 fiber
ITU-T G.957 application code
SSS Single optical module with single bi-directional fiber (slave),
1310 nm receive and 1550 transmit, SC optical connector,
30 km reach (20dB) - S1.1/ S1.2 1550 nm from slave to master
Order SSS to use with SSM
Use 1 fiber
ITU-T G.957 application code
For other optical modules:
MMSnn Other special optical modules for special order nn = 01 to 99
(contact sales for details)
where x is used to select ABCD signaling bits type:
x = Description Note
E Follows ETSI signaling bits
A Follows ANSI signaling bits Jamper selectable for all channels
R Reverse for ON-HOOK and OFF-HOOK signaling bits exchange
S Follows customer抯 special bit or function assignment
AR Follows ANSI signaling bits and reverse bit
SAA Single optical module with dual uni-directional fiber, 1310 nm,
SC optical connector, 30 km reach (20dB) - S1.1 Use dual fiber
Units delivered ITU-T G.957 application code
SBB Single optical module with dual uni-directional fiber, 1310 nm,
SC optical connector, 50 km reach (30dB) - L1.1
SCC Single optical module with dual uni-directional fiber, 1310 nm,
FC optical connector, 30 km reach (20dB) - S1.1
SDD Single optical module with dual uni-directional fiber, 1550 nm,
SC optical connector, 20 km reach (12dB) - S1.2
SEE Single optical module with dual uni-directional fiber, 1550 nm,
SC optical connector, 100 km reach (40dB) - L1.2
SSM Single optical module with single bi-directional fiber (master),
1310 nm transmit and 1550 receive, SC optical connector,
30 km reach (20dB) - S1.1/ S1.2 1310 nm from master to slave
Order SSM to use with SSS
Use 1 fiber
ITU-T G.957 application code
SSS Single optical module with single bi-directional fiber (slave),
1310 nm receive and 1550 transmit, SC optical connector,
30 km reach (20dB) - S1.1/ S1.2 1550 nm from slave to master
Order SSS to use with SSM
Use 1 fiber
ITU-T G.957 application code
For other optical modules:
MMSnn Other special optical modules for special order nn = 01 to 99
(contact sales for details)
where x is used to select ABCD signaling bits type:
x = Description Note
E Follows ETSI signaling bits
A Follows ANSI signaling bits Jamper selectable for all channels
R Reverse for ON-HOOK and OFF-HOOK signaling bits exchange
S Follows customer抯 special bit or function assignment
AR Follows ANSI signaling bits and reverse bit
About Us
We Loop Suzhou is the 100% subsidiary of Loop Telecommunication International Inc, which located in Taiwan. Loop Telecommunication International Inc, a global-market-oriented company, specializing in the line of digital communication access solutions, supported by strong research and development, quality control, selling and service staff.
Loop provides access network products to network service providers, system integrators, and large enterprises with private networks all over the world. The product ranges from CSU/DSU, media converters, xDSL, and fiber optical modems to multiplexers (E1/T1, SDH/SONET), DACS, FR/ATM access cards, and access routers. The installation base has been established in more than 60 countries.
Loop provides access network products to network service providers, system integrators, and large enterprises with private networks all over the world. The product ranges from CSU/DSU, media converters, xDSL, and fiber optical modems to multiplexers (E1/T1, SDH/SONET), DACS, FR/ATM access cards, and access routers. The installation base has been established in more than 60 countries.
Business Type: Manufacturer/OEM
Main Products
CSU/DSU, media converters, xDSL, and fiber optical modems to multiplexers (E1/T1, SDH/SONET), DACS, FR/ATM access cards, and access routers.
Contact Details
View similar products inWireless Networking Equipment
I want to purchase