Prostar Pure Sine Wave Power Inverter (300W-5000W)
Inquire Now
Description
A power inverter, or inverter, is an electronic device or circuitry that changes direct current (DC) to alternating current (AC). The input voltage, output voltage and frequency, and overall power handling depend on the design of the specific device or circuitry. The inverter does not produce any power; the power is provided by the DC source. A power inverter can be entirely electronic or may be a combination of mechanical effects (such as a rotary apparatus) and electronic circuitry. Static inverters do not use moving parts in the conversion process.
Prostar home power inverters is complete functional dc to ac inverter, but not module, and the frame of each dc ac inverter is completely same. It can be used parallel, and also can be used singly. In a system, when it is working, the master dc to ac Prostar home power inverter must be power on, and the working quantities of the other slave inverters depend on the usage of the load. So it very convenient to use and can maximum reduce the power loss of no load in the system.
Prostar home power inverters is complete functional dc to ac inverter, but not module, and the frame of each dc ac inverter is completely same. It can be used parallel, and also can be used singly. In a system, when it is working, the master dc to ac Prostar home power inverter must be power on, and the working quantities of the other slave inverters depend on the usage of the load. So it very convenient to use and can maximum reduce the power loss of no load in the system.
Features
Pure sine wave inverter
Wide input voltage range
With strong load performance and wide application range
15 A standard charging current
Intelligent Charger
Auto restart while AC is recovering
High efficiency and energy saving
Overload, deep discharge, overcharge, and short circuit protection
Cold start function
Built-in solar charger (Option)
Offering LED or LCD front panels for selection
Wide input voltage range
With strong load performance and wide application range
15 A standard charging current
Intelligent Charger
Auto restart while AC is recovering
High efficiency and energy saving
Overload, deep discharge, overcharge, and short circuit protection
Cold start function
Built-in solar charger (Option)
Offering LED or LCD front panels for selection
Specification
Place of Origin: Guangdong, China
Brand Name: Prostar or OEM/ODM
Certification: CE,RoHS,ISO9001,ISO14001
Model Number: AN1K
Wave Form: Pure Sine Wave
Transfer Time: 4ms
Power: 1000W
Battery Type: Sealed Maintenance Free Lead Acid Battery
Battery Voltage: 24Vdc
Product Features: Power inverter
Product Series: 7000 Series
Max. Charging Current: 10A
Size: 130x375x190mm
Weight: 15.8Kgs
Input Voltage: 100/110/120/127/220/230Vac
Output Voltage: 100/110/120/127/220/230Vac ?3%
Output Frequency: 50Hz/60Hz?.5
Output Current: 10A
Output Power: 1000W
Output Type: Single
Type: DC/AC Inverters
Brand Name: Prostar or OEM/ODM
Certification: CE,RoHS,ISO9001,ISO14001
Model Number: AN1K
Wave Form: Pure Sine Wave
Transfer Time: 4ms
Power: 1000W
Battery Type: Sealed Maintenance Free Lead Acid Battery
Battery Voltage: 24Vdc
Product Features: Power inverter
Product Series: 7000 Series
Max. Charging Current: 10A
Size: 130x375x190mm
Weight: 15.8Kgs
Input Voltage: 100/110/120/127/220/230Vac
Output Voltage: 100/110/120/127/220/230Vac ?3%
Output Frequency: 50Hz/60Hz?.5
Output Current: 10A
Output Power: 1000W
Output Type: Single
Type: DC/AC Inverters
Safety/Quality Approvals
CE
Other 1
Applied Scope
Office Automation
Medical & Education
Industrial Automatic Control
Electronic & Telecom
Data Center
Finance & Securities
Home Using
Production Equipment
Broadcasting & Transportation
Warranty
One year warranty after the date of delivery.
Payment Terms
Terms of payment is T/T or L/C. 30% deposit before production, 70% balance before shipment.
FAQ
1.Can I support Air-Conditioning on my UPS?
Air-Conditioning can be considered as a irty?load due to continual switching causing voltage and current spikes and surges. The UPS module can cater for a certain level of overload for a small duration, however the duration and level of current surges typically associated with A/C units is far greater than the UPS?capability. Therefore it is advised not to support the AC on a UPS and supply this element with a generator only if possible. If there is no option but to support the AC using a UPS, it is normal to oversize the inverter by 4-5 times to ensure that the unit will cater for this more demanding load and eliminate any risk to the critical load. Another sensible approach to reduce any risk is toeth critical load is to have a seperate dedicated UPS for the A/C requirement.
2.Why choose 'Transformer-based' or 'Transformer-less' UPS?
Transformer based Traditional technology, typically available from 10 kVA, suitable for industrial applications, galvanic isolation with inverter output transformer, typically standard technology from 100 kVA upwards
Transformer-less Typical technology from the smallest ratings up to 120 kVA, more compact footprints, lower weights, more suited to IT applications and environments, high efficiency across the load range, generally more cost effective.
3.Can I add more UPS modules to the system when my load increases?
Yes, our SU, HM and HT ranges employ a plug and play parallel system that allows additional units to be added to an existing system at a later date. Additional UPS units can be added to either provide redundancy or extra capacity if the load increases. Sometimes it worth investing in additional switchgear early on so that more units can be accommodated much more easily.
4.Why do you need a UPS?
An Uninterruptible Power Supply (UPS) is used to protect critical loads from mains supply problems, including spikes, voltage dips, fluctuations and complete power failures using a dedicated battery. A UPS system can also be used to ridge the gaphilst a standby generator is started and synchronised.
http://www.ueduo.cn/sell-1463913-prostar-dc-to-ac-1000w-power-inverter-with-battery-charger-an1k.html
Office Automation
Medical & Education
Industrial Automatic Control
Electronic & Telecom
Data Center
Finance & Securities
Home Using
Production Equipment
Broadcasting & Transportation
Warranty
One year warranty after the date of delivery.
Payment Terms
Terms of payment is T/T or L/C. 30% deposit before production, 70% balance before shipment.
FAQ
1.Can I support Air-Conditioning on my UPS?
Air-Conditioning can be considered as a irty?load due to continual switching causing voltage and current spikes and surges. The UPS module can cater for a certain level of overload for a small duration, however the duration and level of current surges typically associated with A/C units is far greater than the UPS?capability. Therefore it is advised not to support the AC on a UPS and supply this element with a generator only if possible. If there is no option but to support the AC using a UPS, it is normal to oversize the inverter by 4-5 times to ensure that the unit will cater for this more demanding load and eliminate any risk to the critical load. Another sensible approach to reduce any risk is toeth critical load is to have a seperate dedicated UPS for the A/C requirement.
2.Why choose 'Transformer-based' or 'Transformer-less' UPS?
Transformer based Traditional technology, typically available from 10 kVA, suitable for industrial applications, galvanic isolation with inverter output transformer, typically standard technology from 100 kVA upwards
Transformer-less Typical technology from the smallest ratings up to 120 kVA, more compact footprints, lower weights, more suited to IT applications and environments, high efficiency across the load range, generally more cost effective.
3.Can I add more UPS modules to the system when my load increases?
Yes, our SU, HM and HT ranges employ a plug and play parallel system that allows additional units to be added to an existing system at a later date. Additional UPS units can be added to either provide redundancy or extra capacity if the load increases. Sometimes it worth investing in additional switchgear early on so that more units can be accommodated much more easily.
4.Why do you need a UPS?
An Uninterruptible Power Supply (UPS) is used to protect critical loads from mains supply problems, including spikes, voltage dips, fluctuations and complete power failures using a dedicated battery. A UPS system can also be used to ridge the gaphilst a standby generator is started and synchronised.
http://www.ueduo.cn/sell-1463913-prostar-dc-to-ac-1000w-power-inverter-with-battery-charger-an1k.html
About Us
Foshan Prostar Science & Technology Development Co.,Ltd. (named as Prostar UPS)is an enterprise jointly invested by the U.S., Taiwan and Mainland China with more than many years for manufacturing and trading experience.
Prostar was set up in 1988, specializes in the design and production high quality OEM and Prostar own brand of industrial Uninterruptible Power Supply (UPS), Power Inverter, Solar panels, Solar Power generation system and Wind Power generation system,and Emergency Power Supply (EPS) as well as maintenance-free lead acid battery.
Prostar has a very experienced and professional Design and Research Department who work closely with customers for their product development as well as designing the ever expanding Prostar brand range. Other divisions include Quality Control Centre, Purchasing & Production Centre, and Sales and Customer Service Centre.
Prostar is wholly responsible for the business promotion and service in the Mainland China. Through a decade of great efforts, Prostar has made the poster branded series of power supplies and batteries widely used in the fields of finance, telecom, electric power, petrol chemistry, finance and taxation of China, and been honorably commented by clients. Taking and making world-class products with professionally earnest attitude as its responsibility, Prostar insists on constant study and innovation to strive to ascend the new summit of the career. We proudly stick to the spirit of "Sincerity, Cooperation, Competitiveness and Creativity ".
Foshan Prostar Science & Technology Development Co.,Ltd. possesses numerous experienced technical personnel, and all of our employees have been subject to professional technical training and examination. Prostar passed the authentication of ISO9001, CE and IQNet (worldwide member countries more than 30). The strict and careful quality management gives clients great confidence. For years, the Prostar branded products are widely distributed throughout Europe as well as Affrica, Oceania, Southeast Asia, South America and the Middle East.
Through the integration and optimization of resources, Prostar focus on the strategic planning of Quality, Structure, Marketing, Fashion and Innovation. Upholding the principle of "Customer and Credibility First", we believe that optimization of efficient quality is the prerequisite of our ultimate goal of customer satisfaction. We invite all our customers to support us and work closely together to achieve mutual benefit. Sincerely hope we can be of service to you in the near future! For inquiries, you can send us an e-mail at
【Company Video】
If you need to learn more information about Prostar UPS, please watch our company video via our youtube: http://youtu.be/LKEPpqhMzHk
Established Date: 1998/1/2
No. of Employees: 152 Persons
Business Type: Manufacturer/OEM
Main Products
Uninterruptible Power Supply