Description :
*ITE 60950-1, 62368-1 & Medical 60601-1 approvals. ( Class I )
*3-prong IEC320-C14, Class I (I/O Switch Option)
*Medical safety approved ( 2x MOPP between primary to secondary )
*Suitable for BF application with appropriate system consideration.
*Altitude during operation: ITE/Medical up to 5000m.
*≦ 0.15W No Load Input Power
*Touch current less than 100uA
*Meet IEC60601-1-2 Ed4:2014
*3 year warranty
Features :
*Dimension : L 200×W 90×H45 mm ( 7.874"x3.543"x1.77" )
*Weight : 1.3 kgs. ( 2.87 lbs. )
Specification :
Electrical specifications
  • Input range : 90 - 264VAC
  • Frequency : 47 - 63Hz
  • Power Factor : > 0.95 @115VAC; > 0.90 @230VAC @full load
  • Inrush current : < 80A peak @115VAC; < 80A peak @230VAC cold start @25°C
  • Input current (rms) : 2.5A @115VAC; 1.3A @230VAC max.
  • Efficiency : > 89% (Average) 25 %, 50 %, 75 % and 100 % of full load @ 115/230VAC
  • Touch current < 100uA @264VAC
  • Maximum output power (Po) : 250 Watts convection cooling
  • Hold-up time : > 10ms typical @full load, 115VAC
  • Short circuit protection : Auto-recovery
  • Over load protection : 105% to 160% maximum power, Auto-recovery
  • Over voltage protection : Auto-recovery
Safety standards
  • UL/cUL 60601-1 3.1rd Edition
  • TUV EN60601-1 3.1rd Edition
  • CB IEC 60601-1 3.1rd Edition
  • UL/c-UL UL60950-1
  • UL/c-UL UL62368-1
  • TUV EN60950-1
  • TUV EN62368-1
  • CB IEC 60950-1
  • CB IEC 62368-1
EMC standards
  • EN60601-1-2 Ed4:2015
  • IEC60601-1-2 Ed4:2014
  • EN 55011 Class B
  • EN 55032 Class B
  • EN 55024 Class B
  • FCC Part 15 Class B
  • FCC Part 18 Class B
  • CE.
Environmental
  • Operating temperature : -20 to +60°C (Refer to "Derating Curve")
  • Cooling:Convection-cooling
  • Storage temperature : -20°C to +85°C
  • Humidity: Non-condensing 0% ~ 95%.
  • MTBF : > 200,000 hours @full load and 25°C ambient temperature based on Bellcore TR-332
DC OUTPUT & FEATURES
Model Output Rating Po O/P regulation Ripple & Noise
(Vp-p)
DOE Efficiency Eu ErP
PW-250A-1Y120P1MZ +12V 20.83A 250W ±5% 240mV VI tier 2
PW-250A-1Y190P1MZ +19V 13.157A 250W ±5% 300mV VI tier 2
PW-250A-1Y240P1MZ +24V 10.416A 250W ±5% 300mV VI tier 2
PW-250A-1Y280P1MZ +28V 8.928A 250W ±5% 300mV VI tier 2
PW-250A-1Y360P1MZ +36V 6.94A 250W ±5% 300mV VI tier 2
PW-250A-1Y480P1MZ +48V 5.208A 250W ±5% 300mV VI tier 2
PW-250A-1Y540P1MZ +54V 4.629A 250W ±5% 250mV VI tier 2
Note:
1. Ripple and noise are measured at oscilloscope 20MHz bandwidth by a 47uF electrolytic capacitor and a 0.1uF ceramic capacitor in parallel at output connector.
2. AC INLET : IEC 320-C14(3PIN)
3. Z = S to denote With I/O Switch, Z = X to denote Without I/O Switch.

Send Message (Your message will be sent directly)

Please enter only English message between 20 and 900 characters

Contact Information

Please enter First and Last Name


More Exposure,
More Buyers Match,
Unlimited Number of Products.
Apply now !
Wonpro Co., Ltd.