POWER-WIN TECHNOLOGY CORP.
|
Item Number.:
|
PW-250A-1YXXXP1MZ |
Product Name:
|
ITE/Medical AC/DC Power Adapter AD-A12 Series 250Watts |
Description:
|
*ITE 60950-1, 62368-1 & Medical 60601-1 approvals. ( Class I )
*3-prong IEC320-C14, Class I (I/O Switch Option)
*Medical safety approved ( 2x MOPP between primary to secondary )
*Suitable for BF application with appropriate system consideration.
*Altitude during operation: ITE/Medical up to 5000m.
*≦ 0.15W No Load Input Power
*Touch current less than 100uA
*Meet IEC60601-1-2 Ed4:2014
*3 year warranty
|
Features:
|
*Dimension : L 200×W 90×H45 mm ( 7.874"x3.543"x1.77" )
*Weight : 1.3 kgs. ( 2.87 lbs. )
|
Specification:
|
Electrical specifications
- Input range : 90 - 264VAC
- Frequency : 47 - 63Hz
- Power Factor : > 0.95 @115VAC; > 0.90 @230VAC @full load
- Inrush current : < 80A peak @115VAC; < 80A peak @230VAC cold start @25°C
- Input current (rms) : 2.5A @115VAC; 1.3A @230VAC max.
- Efficiency : > 89% (Average) 25 %, 50 %, 75 % and 100 % of full load @ 115/230VAC
- Touch current < 100uA @264VAC
- Maximum output power (Po) : 250 Watts convection cooling
- Hold-up time : > 10ms typical @full load, 115VAC
- Short circuit protection : Auto-recovery
- Over load protection : 105% to 160% maximum power, Auto-recovery
- Over voltage protection : Auto-recovery
Safety standards
- UL/cUL 60601-1 3.1rd Edition
- TUV EN60601-1 3.1rd Edition
- CB IEC 60601-1 3.1rd Edition
- UL/c-UL UL60950-1
- UL/c-UL UL62368-1
- TUV EN60950-1
- TUV EN62368-1
- CB IEC 60950-1
- CB IEC 62368-1
EMC standards
- EN60601-1-2 Ed4:2015
- IEC60601-1-2 Ed4:2014
- EN 55011 Class B
- EN 55032 Class B
- EN 55024 Class B
- FCC Part 15 Class B
- FCC Part 18 Class B
- CE.
Environmental
- Operating temperature : -20 to +60°C (Refer to "Derating Curve")
- Cooling:Convection-cooling
- Storage temperature : -20°C to +85°C
- Humidity: Non-condensing 0% ~ 95%.
- MTBF : > 200,000 hours @full load and 25°C ambient temperature based on Bellcore TR-332
DC OUTPUT & FEATURES
Model |
Output Rating |
Po |
O/P regulation |
Ripple & Noise
(Vp-p) |
DOE Efficiency |
Eu ErP |
PW-250A-1Y120P1MZ |
+12V |
20.83A |
250W |
±5% |
240mV |
VI |
tier 2 |
PW-250A-1Y190P1MZ |
+19V |
13.157A |
250W |
±5% |
300mV |
VI |
tier 2 |
PW-250A-1Y240P1MZ |
+24V |
10.416A |
250W |
±5% |
300mV |
VI |
tier 2 |
PW-250A-1Y280P1MZ |
+28V |
8.928A |
250W |
±5% |
300mV |
VI |
tier 2 |
PW-250A-1Y360P1MZ |
+36V |
6.94A |
250W |
±5% |
300mV |
VI |
tier 2 |
PW-250A-1Y480P1MZ |
+48V |
5.208A |
250W |
±5% |
300mV |
VI |
tier 2 |
PW-250A-1Y540P1MZ |
+54V |
4.629A |
250W |
±5% |
250mV |
VI |
tier 2 |
Note:
1. Ripple and noise are measured at oscilloscope 20MHz bandwidth by a 47uF electrolytic capacitor and a
0.1uF ceramic capacitor in parallel at output connector.
2. AC INLET : IEC 320-C14(3PIN)
3. Z = S to denote With I/O Switch, Z = X to denote Without I/O Switch.
|
|
|
|
|
 |
Send Message
(Your message will be sent directly)
|
|
|
|
|
|